Features
The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It has protection against voltages above 600V in all ranges and an audible and optical alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlight and fast refresh rate (3 times/sec). The opening of the jaws allows the measurement of cables with a diameter of up to 28 mm. Non-contact electric field detection (NCV) allows detecting live conductors in two sensitivities - EFLo and - EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz. The probe tip cover provided on the test leads allows measurement in CAT III category LV distribution without the risk of arcing. Without end caps, test leads can only be measured on CAT II category low voltage distribution lines. 2pcs 1.5V R03 power battery. The power consumption of the meter is approx. 1.8 mA. The circuit has an automatic energy saving function. Standby consumption is <11µA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- Measurement of voltage, current and frequency of high voltage up to 600 V
- Non-contact electric field detection (NCV)
- Frequency measurement from 10 Hz to 10 MHz
- Measurement of capacity 6nF to 60mF
- Measurement of ratio (relative) of voltages and capacitances
- Multi - segment display and audible / visual alarm
- Protection against voltages greater than 600 V at ranges
- Automatic range switching
- The accuracy of current and voltage measurements is guaranteed in the range of 1% to 100% of the ranges
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
- 6,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% + 10)
- 60.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% + 10)
- 600.0 A / 0.100 A / 50 Hz ~ 100 Hz ± (2.0% + 10)
- A Frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) in the resolution of 0.1 Hz
- Overload protection at 620A
2. AC voltage measurement (range / resolution / accuracy):
- 6,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% + 5)
- 60.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% + 5)
- 600.0V / 0.100V / 10Hz ~ 10kHz ± (0.8% + 5)
- Monitoring accuracy of frequency when measuring AC voltage in the range of 10 to 10k ± (1.0% + 5) at a resolution of 0.01 Hz to 0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10MGO
3. DC voltage measurement (range / resolution / accuracy):
- 600.0mV / 0.100mV / ± (0.7% + 3)
- 6,000 V / 0.001 V / ± (0.5% + 2)
- 60.00 V / 0.010 V / ± (0.7% + 3)
- 600.0 V / 0.100 V / ± (0. 7% + 3)
- Input impedance approx. 10MO
- Overload protection at 600Vrms
4. Resistance measurement (ranges / resolution / accuracy):
- 600.0O / 0.1O / ± (1.0% + 2)
- 6,000kO / 0.001kO / ± (0.8% + 2)
- 60.00kO / 0.01kO / ± (0.8% + 2)
- 600.0kO / 0.1kO / ± (0, 8% + 2)
- 6,000MO / 0.001MO / ± (2.0% + 5)
- 60.00MO / 0.01MO / ± (2.0% + 5)
- Overload protection at 600 Vrms
5. Capacity measurement (ranges / resolution / accuracy):
- 6,000nF / 0.001nF / ± (4.0% + 10)
- 60.00nF / 0.01nF / ± (4.0% + 10)
- 600.0nF / 0.1knF / ± (4.0% + 10)
- 6,000µF / 0.001µF / ± (4.0% + 5)
- 60.00µF / 0.01µF / ± (4.0% + 5)
- 600.0µF / 0.1µF / ± (4.0% + 5)
- 6,000mF / 0.001mF / ± 10.0%
- 60.00mF / 0.01mF / ± 10.0%
- Overload protection at 600 Vrms
6. Frequency and load measurement (ranges / resolution / accuracy):
- Frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
- Filling: 0.1 to 99.9% / 0.1% / ± (3.0% + 5)
- Note 1) Measurement sensitivity:
= 100kHz: 200mVrms = input amplitude = 30V RMS
> 100kHz ~ 1MHz: 600mV RMS = input amplitude = 30V RMS
> 1MHz ~ 10MHz: 1V RMS = input amplitude = 30V RMS
- Note 2) Fill measurement (work rate) is only applicable for square wave =10kHz, amplitude: 1V pp
Frequency = 1kHz Work rate (fill): 10.0% ~ 95, 0%
Frequency > 1kHz Working rate (filling): 30.0% ~ 70.0%
- Overload protection at 600 Vrms
7. Circuit continuity check:
- If the measured resistance is less than 10O, the continuous circuit signal sounds a beep
- If the measured resistance is greater than 31alizace, open circuit signal does not sound a bell
- Open circuit voltage about 2.0 V
- Measurement in the range of 600O
- Overload protection at 600 Vrms
8. Diode measurement:
- In the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2 V
- For a silicon junction, a typical voltage drop is 0.5 to 0.8 V
- Open circuit voltage of about 3.9 V - measurement in the range of 6000 V
Other parameters:
- Measurement of maximum and minimum values: yes
- Measurement in relative mode (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- Low battery indication: yes
- Auto power off: yes
- Battery power 1.5V (R03 ): 2pcs
- Backlit screen size: 37 mm x 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- Product net weight: 248 g
- Product color: red and gray
Package Contents:
- Clip Multimeter UT201R: 1 unit
- Test leads: 1 pair
- Battery 1.5V (R03): 2pcs
- Instructions for use: 1pc